1. Switch the LMI to bypass position. And then press the telescoping manual button.

 

2. Use the lever to position desired boom section (IK: 1 or 2, 3, 4) and the cylinder pin position sensor (VPS, NPS) until both of indicator lamp light up. And then press the cylinder pin push button. (The boom position and cylinder pin changes in the order 1 > 12 > 2)

 

3. When the boom pin position sensor (VPV, NPV) both of indicator lamp light up. And then press the boom pin retract button. If the boom pin button show red light, press it once more to remove the red light (The boom position and cylinder pin changes in the order of 2> 23 >3)

 

4. Use the lever to retract the boom. At the same time boom pin position sensor (VPV, NPV) both of indicator lamp light up. And then press the boom pin push button. If the boom pin button show red light, press it once more to remove the red light (The position of the boom / Cylinder pin changes in the order of 3> 23 >2)

 

5. Use the lever to move the cylinder so that the cylinder pin position sensor (VPV, NPV) until both of indicator lamp light up, And then press the cylinder pin retract button. (The boom position and cylinder pin changes in the order of 2 > 12 > 1)

 

6. Use the lever to move cylinder and boom all position back to telescoping until length indicator show 0m.

 

7. Press the telescoping teaching button and enter the current boom status (For example, if the boom is extend at 100% for the first stage and 90% for the second stage) In the Teaching window it show telescoping current status (T1: 100 / T2: 90 / T3: 0 / T4: 0 / TS: 0)

 

8. Return the LMI bypass key to its original state

 

Pre PAT System error list 2019-08-09
Next BENZ engine oil guide 2019-07-22
Back